Need Help? Call 270-781-2229  
   CED - BOWLING GREEN   
View Cart CART  
 Shop by Category  ( Show All )

Back

Top Sellers in Distribution Equipt - Circuit Breakers

   
Show  items per page    First Previous  Page   of  14  Next Last
CIRCUIT BREAKER
CUTLER HAMMER VECTROL
CHF120
1P 120/240V 20A TYPE CH BREAKER
THERMAL MAGNETIC; 120/240 VAC VOLTAGE RATING; 20 AMPERE CURRENT RATING; 1 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL ALUMINUM/COPPER WIRE; APPROVAL UL 489, CSA C22.2; CH MODEL; FEATURES SWITCHING DUTY RATED, HACR RATED, TRIP INDICATION

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
189
CUTLER HAMMER VECTROL
CHFAFGF120PN
1P 20A CH PON AFCI / GFCI BREAKER

Show all:  Ground Fault Gfci Plug-In Circuit Breakers

 More Details
113
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
CH260
2P 120/240V 60A TYPE CH BREAKER
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 60 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 14 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489, CSA; USED ON LOAD CENTER; CH MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
52
CIRCUIT BREAKER
CUTLER HAMMER VECTROL
CHF230
2P 120/240V 30A TYPE CH BREAKER
THERMAL MAGNETIC, COMMON TRIP; 120/240 VAC VOLTAGE RATING; 30 AMPERE CURRENT RATING; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL ALUMINUM/COPPER WIRE; APPROVAL UL 489, CSA C22.2; CH MODEL; FEATURES HACR RATED, TRIP INDICATION

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
50
CIRCUIT BREAKER
CUTLER HAMMER VECTROL
CHF115
1P 120/240V 15A TYPE CH BREAKER
THERMAL MAGNETIC; 120/240 VAC VOLTAGE RATING; 15 AMPERE CURRENT RATING; 1 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL ALUMINUM/COPPER WIRE; APPROVAL UL 489, CSA C22.2; CH MODEL; FEATURES SWITCHING DUTY RATED, HACR RATED, TRIP INDICATION

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
177
CIRCUIT BREAKER
CUTLER HAMMER VECTROL
CHF240
2P 120/240V 40A TYPE CH BREAKER

Show all:  Standard Trip Plug-In Circuit Breakers

 More Details
58
ARC FAULT CIRCUIT INTERRUPTER
CUTLER HAMMER VECTROL
CHFCAF115PN
1P 15A CH PON ARC FAULT BREAKER

Show all:  Arc Fault Afci Plug-In Circuit Breakers

 More Details
141
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR120
1P 120/240V 20A TYPE BR BREAKER
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
338
COMBINATION ARC FAULT CIRCUIT INTERRUPTER
CUTLER HAMMER VECTROL
CHFCAF120PN
1P 20A CH PON ARC FAULT BREAKER

Show all:  Arc Fault Afci Plug-In Circuit Breakers

 More Details
148
CUTLER HAMMER VECTROL
CHFAFGF115PN
1P 15A CH PON AFCI / GFCI BREAKER

Show all:  Ground Fault Gfci Plug-In Circuit Breakers

 More Details
168
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
CH2100
2P 120/240V 100A TYPE CH BREAKER
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 100 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489, CSA; USED ON LOAD CENTER; CH MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
9
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR220
2P 120/240V 20A TYPE BR BREAKER
THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
39
CUTLER HAMMER VECTROL
CHFGFT115PN
1P 120V 15A PON GRD FAULT ST BRKR

Show all:  Ground Fault Gfci Plug-In Circuit Breakers

 More Details
25
CIRCUIT BREAKER
CUTLER HAMMER VECTROL
CHF220
2P 120/240V 20A TYPE CH BREAKER
THERMAL MAGNETIC, COMMON TRIP; 120/240 VAC VOLTAGE RATING; 20 AMPERE CURRENT RATING; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL ALUMINUM/COPPER WIRE; APPROVAL UL 489, CSA C22.2; CH MODEL; FEATURES HACR RATED, TRIP INDICATION

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
18
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
CH240
2P 120/240V 40A TYPE CH BREAKER
COMMON TRIP, THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 40 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 14 TO 2 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489, CSA; USED ON LOAD CENTER; CH MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
2
* E=Each, C=100, M=1000
First Previous  Page   of  14  Next Last
 
 


1390 CAMPBELL LANE BOWLING GREEN, KY 42104 | Tel: 270-781-2229 | Fax: 270-781-4843 | customerservice@cedbgky.com
Terms of Use | Terms and Conditions
3.5.4